EDS 3X Release Notes
Stay up to date with the latest improvements and bug fixes in EDS software version 3X. This update brings exciting features such as enhanced device polling, improved system resource usage, support for our Sentinel continuous monitor, and device discovery via IP address. Explore the full changelog to discover more enhancements and fixes that optimize your EDS experience.
Removed Options
- Windows Service
- EDS Webpage
Added Features and Fixes
- Improves device polling and data transmission speed
- Improves system resource usage
- Adds support for our Sentinel continuous monitor
- Adds support for device discovery via IP address
- Adds support for Oracle MySQL database (Enterprise only)
- Adds ability to capture device name and location
- Adds an uncapped limit on supervisors
- Adds a network latency meter in the devices tab
- Adds additional error logs for network related issues
EDS 3X Changelog
v3.1.41 (Beta)
- Enhanced Network Fault Tolerance: Improved resilience to network faults for more reliable connectivity.
- New Feature – Force Device Discovery: Added the ability to initiate forced device discovery for environments where UDP port 30303 traffic may be inconsistent.
- App Versioning in Configuration: Integrated application versioning in the EDS configuration file for easier version tracking and management.
- Performance Enhancements: Various optimizations to improve overall application performance.
v3.1.40
- Improves network stability
- The application is now digitally signed.
- Renamed “Footwear Insolative Test” to “Footwear Insulative Test”.
- Renamed the check box labeled “SSL” to “TLS 1.2” in the properties window.
- Renamed “signal wire” to “wrist” everywhere except in reports to maintain backward compatibility.
- Fixed AllDayTestData option in reporting.
- Fixed issue when enabling windows FIPS Compliance via GPO, FIPS can now be enabled.
- Fixed “Time” column issue in MYSQL and MSSQL.
- Added two new database columns “Smock Resistance Wire 2” and “Wrist Resistance Wire 2” for elites on firmware version 3.00.23aa and above.
- Added a check (when uploading users to a device) to verify that employee number and tester number are not over 12 characters.
- Added device online indicator [Online/Total], at the bottom of the main window.
- Added SQL type indicator, at the bottom of the main window.
- Added more information in the log files.
- Added the ability to reorder columns and automatic column resizing in the Users tab and the Test Results tab.
v3.1.39
- Fixed an issue with scheduled email report displaying incorrect column name when smock feature is enabled
- Added support to auto re-discover devices in a limited broadcast environment
- Security updates
v3.1.38
- Security updates
v3.1.37
- Dotnet Framework 4.6.2 is now the minimum requirement
v3.1.36
- Increase tolerance for high latency networks
- Diagnosis\logs changed file name prefix and file extension from ‘LogFileyyyyMMdd.txt’ to ‘Diag-yyyyMMdd.log’
v3.1.35
- Added support for MySQL running on Linux
v3.1.34 (Latest Release)
- Fixed an issue where the Microsoft Access database was entering the date incorrectly on test records when using a UK date format between the 1st and 12th of every month.
- Fixed an issue that only allowed 11 departments to be created, now there is no limit.
v3.1.33
- Changed general communications security from TLS 1.0 to TLS 1.2.
v3.1.32
- Fix for sorting Sentinel data
v3.1.31
- Fix for Sentinel discovery.
v3.1.30
- Fix for adding devices into the software.
- Fix for high system resource usage.
- Adds support for device discovery via IP address.
- Adds support for limiting which network adapters are used for device discovery.
v3.1.29
- Fix for TCP timeouts, this resolves most user upload issues.
v3.1.28
- Fix for adding supervisors, the ~100 supervisor limit has been removed.
v3.1.27
- Added a network latency display to devices in the devices tab.
- Added logging for failed user uploads.
v3.1.26
- Fix for enterprise key activation.
v3.1.24
- Removed unused button.
v3.1.23
- Fix for report error condition regarding unfiltered ordering.
v3.1.22
- Fix for the reports tab.
v3.1.21
- Fix for sentinel reports using the MS access database type.
- Fix for some events not showing up.
v3.1.20
- Fix for email reporting bugs.
v3.1.19
- Fix for backup logs.
v3.1.18
- Added feature/sentinel report.
- Added sentinel reporting feature.
- Fix for MySQL connection string.
- Fix for Sentinel not showing unit tag and location.
v3.1.17
- Fix for MySQL database connection.
v3.1.16
- Fix for device update pushes not working.
v3.1.15
- Fix for memory bug – 3 of 3.
- Improved event reporting performance.
- Added support for MySQL DB.
v3.1.14
- Fix for memory bug – 2 of 3.
v3.1.13
- Fix for memory bug – 1 of 3.
v3.1.12
- Code optimization.
v3.1.11
- Updated SentinelView, displays voltage and resistance values.
v3.1.10
- Merged sentinel and cmEvent views.
v3.1.9
- Fix for balance between user upload and test log download.
- Fix for device view color not updating.
- Added Sentinel status in the devices tab.
v3.1.8
- Fix for data transfer issues between user upload and test log download.
v3.1.7
- Fix for slow user upload.
- Added “cmevents-backup.log” for messages that fail to insert in the database.
v3.1.6
- Fix for user upload not working.
v3.1.5
- Fix for test and retest user updates not working simultaneously.
- Fix for user upload and test log upload for Elitev1.
- Fix for logging.
- Fix and performance improvement to receiving SentinelV2 test logs.
- Fix for crashes to always log errors.
- Fix for improved logging.
- Added ability to import/export csv files.
v3.1.4
- Code optimization.
v3.1.3
- Code optimization.
v3.1.2
- Fix for event data.
- Fix for user upload.
- Fix for the Elite v1 Serial COM.
- Fix for corrupted test logs, they are now saved in a backup file
- Fix for user filter DataGridViews, they are now set to readonly.
- Fix for invalid test logs, they are now saved separately from those that had a database issue.
- Fix for an issue when the Elite v1 checks the realport driver for device existence.